Centro Fermi
 
 
Centro Fermi
 

Software

DAQ software

 

New EEE Analyzer v 1.0.7 [download]

Fixed bug in decoding procedure of GPS information to give nanoseconds.

 

Version 1.7.5

Full Project Distribution: EEE Project v 1.7.5.exe

New in version 1.7.5

1. EEE Data Acquisition:
- GPS readout at the beginning of run removed - no GPS structure right after Window-And-Delay data (might be back in the next versions);
- Improved automatic error handling - program will do 3 attempts to recover from CAEN VME-USB Bridge communication errors;

2. EEE Analyzer v1.0.5 included;

3. Recompiled versions with User Data type (codes 10..) added (all compatible with old data):
- EEE HW Address Checker;
- EEE Histogram Builder;
- EEE Pulse Width Converter;
- EEE TXT Converter;
- EEE Byte Order Converter

Programs will just skip such data structures if present in BIN-file, othervice functionality remains the same as before. Users are responsible for proper decoding of such data.

 

Version 1.7.3

Full Project Distribution: EEE Project v 1.7.3.exe

 

Version 1.7.1

Full Project Distribution: EEE Project v 1.7.1.zip

EEE Project was developed with NI LabVIEW 8.2.1, and LV Run-Time Engine v8.2.1 must be installed before any other EEE application.
Please install CAEN VME Demo as it will install CAENVMElib.dll required for EEE Data Acquisition and EEE HW Address Checker programs.
IMPORTANT: This version requires CAEN TDC V1190 firmware Rev0.7 or later. Please update firmware on each TDC in the system!
EEE Pulse Width Converter uses new functionality provided by this update, and therefore cannot be used to process old data files.

New in version 1.7.1

1. EEE Data Acquisition:
- Geometry page added, please check and modify parameters for your station;
- Geometry, Match Window and Delay information stored in binary file, please refer to EEE BIN Format v1.7.1.xls;
- automatic Convert to TXT at the end of acquisition removed, please use EEE TXT Converter instead;
- Fast Restart added to skip TDC re-configuration in Auto Restart mode;
- Angle control fixed;
- Delay writing bug fixed;

2. EEE Histogram Builder:
- Parameters page added;
- Comment and Mode And Resolution indicators moved to Parameters page;
- Geometry, Match Window and Delay information is shown on Parameters page if present in binary file;

3. EEE TXT Converter:
- output TXT file shows Geometry, Match Window and Delay information if present in binary file;

4. EEE Pulse Width Converter:
- Time conversion mode takes into account delay between 1PPS trigger and CLR signal to calculate calibration coefficients, and TDC internal delay.

In case of software installation problem please contact Raman Zuyeuski at CERN:
E-mail: Raman.Zuyeuski AT cern.ch
Phone: +41 (22) 767 7596

 

Version 1.7.0

Full Project Distribution: EEE Project v 1.7.0.zip

 

Version 1.6.0

Full Project Distribution: EEE Project v 1.6.0.zip

 

Vers. 1.5.5

Please install CAEN VME Demo program first as it will install CAENVMElib.dll required for EEE Data Acquisition and EEE HW Address Checker.

EEE Project was developed with NI LabVIEW 8.2.1, and LV Run-Time Engine v8.2.1 must be installed before any other EEE application.

In case of software installation problem please contact Raman Zuyeuski at CERN:

E-mail: Raman.Zuyeuski A T c e r n . c h
Phone: +41 22 767 7596

 


























La Scienza nelle Scuole

:: Portare la Scienza nel cuore dei giovani

:: Motivazione scientifico-culturale

:: Raggi cosmici e corpi celesti

:: Conclusioni

:: Referenze

:: Rivelatori MRPC per muoni

:: Sincronizzazione remota mediante GPS

:: Sciami: rivelazione e simulazione

:: Schema del progetto

:: Enti e Istituzioni

:: Software

:: Collaboratori, Licei ed Insituti

:: Simposio Nazionale 2009

:: Links

       
Centro Fermi